Access Tools

The Access module covers UniFi Access doors, credentials, visitor passes, badge-scan events, and hub / reader hardware. v0.10 ships read-only tools: door unlocks, credential issuance, and visitor-pass creation are deferred to a future v0.11+ that introduces session-token auth alongside the API key (see the v0.10 spec doc for the Option A vs. Option B decision).

The Access module is opt-in. Set:

Terminal window
MCP_UNIFI_MODULES_ENABLED=network,protect,access

If you only want Access (no Network, no Protect):

Terminal window
MCP_UNIFI_MODULES_ENABLED=access

When the env var is unset, only Network is loaded.

Every tool accepts an optional controller: str = "default" parameter. The v0.10 surface has no dry_run parameter because every tool is read-only.

The Access tool surface is intentionally narrow: no door unlocks, no credential issuance, no visitor pass creation, no policy updates, no device reboots. v0.10 covers forensics, audits, summaries, and visibility, which is the bulk of the LLM use cases for Access. Write tools land in a later release gated by a separate explicit decision.

ToolTypedry_runDescription
list_doorsreadList every door bonded to the Access controller. Includes id, name, location, hub_id, locked, online, door_position_status, lock_status, and last_activity (epoch ms).
get_doorreadFetch one door’s full record by ID.
list_door_groupsreadList every door group on the controller. Door groups bundle doors for access-policy assignment.
ToolTypedry_runDescription
list_access_policiesreadList every access policy. Each ties a schedule, one or more door groups, and a set of users / credential types.
get_access_policyreadFetch one access policy’s full record by ID.
ToolTypedry_runDescription
list_credentialsreadList every credential enrolled in the controller. Includes type (nfc, pin, mobile), label, user_id, status, issued_at, expires_at.
get_credentialreadFetch one credential’s full record. Type-specific fields (card_id, pin_length, device_label) come back as well.
audit_expiring_credentialsreadReturn credentials expiring inside the next days_ahead days (default 30). Optional credential_type narrows to one of nfc, pin, mobile. Each entry includes a computed days_until_expiry.
ToolTypedry_runDescription
list_visitorsreadList every visitor pass (active and past).
get_visitorreadFetch one visitor pass’s full record by ID.
ToolTypedry_runDescription
list_access_eventsreadList badge-scan / door events with filters. result filters to granted or denied; empty returns both. door_id narrows to one door.
get_recent_access_eventsreadLast limit events across every door over the last 24h. Convenience wrapper for triage.
summarize_access_activityreadAggregate badge events by door, user, and outcome over the last hours_back hours. Returns total, granted, denied, plus by_door and by_user rollups.
list_failed_access_attemptsreadReturn only result == "denied" events within the window. Each entry includes a reason (expired, off-hours, unknown_pin, etc.).
ToolTypedry_runDescription
list_access_devicesreadList hubs, readers, relays, and intercoms. Includes type (hub or reader), model, firmware_version, online.
get_access_devicereadFetch one Access device’s full record by ID.
ToolTypedry_runDescription
get_access_system_inforeadController version, release channel, license tier (doors_used, doors_max, users_used, users_max), uptime.
list_access_usersreadList every user enrolled in the Access system.

In stub mode, the Access backend exposes:

  • 2 doors (Main Entrance, Server Room) and 1 door group containing both
  • 1 access policy (Business Hours — All Users)
  • 3 credentials, one of each type: NFC card (5-day expiry), PIN (90-day expiry), mobile credential (no expiry)
  • 1 active visitor pass (Dave Delivery)
  • 50 synthetic events spread across the last 24 hours, mixed granted / denied
  • 3 users (Alice Admin, Bob Builder, Carol Contractor)
  • 1 hub and 2 readers (one per door)

Every cross-reference is wired correctly: users[].credential_ids lists the credentials that belong to each user, readers point at their parent door and hub, etc.

  • credential_type (for audit_expiring_credentials): one of "nfc", "pin", "mobile", or empty for all.
  • result (for list_access_events): one of "granted", "denied", or empty for both.

The Access tools require a UniFi Access controller reachable on its own host (often the same gateway as Network, sometimes a standalone hub) with a local Access API key. Set, in addition to the Network connection variables:

Terminal window
UNIFI_ACCESS_HOST=192.168.1.20
UNIFI_ACCESS_PORT=12445
UNIFI_ACCESS_API_KEY=<access-key>

Or, when using a MCP_UNIFI_CONTROLLERS_FILE, set the per-controller access_host, access_port, and access_api_key fields. The Access API key only authorises GETs; the dual-auth path required for writes is not implemented in v0.10.

If MCP_UNIFI_MODULES_ENABLED includes access but no controller has Access credentials configured, calls to Access tools return a clean AccessNotAvailableError envelope rather than failing deep inside the HTTP client.